ZR-3211C UV DOAS Method GAS Analyzer

Short Description:

ZR 3211C  Stack dust( gas)  Tester by UV Differential Optical absorption spectroscopy is a portable instrument. It can measure the concentration of SO2, NOx, O2, H2S, CO, CO2 and other gases by UV Differential Optical Absorption Spectroscopy. It cannot works affected by the water vapor in the flue gas,which is especially suitable for high humidity and low sulfur conditions. It can be used by environmental departments to test the gas concentration and emission from boilers, and can also be used in industrial and mining enterprises to measure the concentration of various harmful gases.


Product Detail

Specification

Applications

> Measurement of SO2 and NOx emission concentration, converted concentration and total emission of all kinds of boilers, industrial furnaces.

> Evaluate and calibrate the accuracy of continuous flue gas measuring instruments.

> Measure flue parameters (dynamic pressure, static pressure, temperature, flow rate, standard dry flow, etc.

> Measure the O2 of gas and excess air coefficient.

Standards

GB13233-2011 fossil-fuel power plant atmospheric pollutant emission standard

GB/T37186-2018 Gas analysis — Determination of sulfur dioxide and nitrogen oxides — ultraviolet differential absorption spectrometric method

HJ 973-2018 Determination of carbon monoxide in exhaust gas from fixed pollution sources constant potential electrolysis

HJ 1045-2019 Technical requirements and detection methods of portable ultraviolet absorption measuring instruments for flue gas (SO2 and NOx) from fixed pollution sources

HJ/T 397-2007 Technical specification for fixed source waste gas monitoring

JJG 968-2002 Verification regulation of flue gas analyzer

Features
> Tested by UV Differential Optical absorption spectroscopy. It can measure the concentration of SO2, NOx, O2and cannot works affected by the water vapor in the flue gas,which is especially suitable for high humidity and low sulfur conditions.

> Automatically switch the range according to the high and low concentration values of SO2, NO and NO2.

> The ultraviolet light source adopts pulse xenon lamp, the preheating time is less than 10min, and the service life is long.

> Support touch and key operation at the same time. 7.0 -inch color screen , wide working temperature , clear Visual in sunshine. The keyboard is dustproof and waterproof, which is suitable for harsh working conditions.

> Self contained battery≥3H.

> Dynamically save sampling data and spectral data, and export excel table.

> Equipped with pitot tube and smoke temperature sensor, it can measure smoke temperature and flow rate.

Deliver Goods

deliver goods Italy
  • Previous:
  • Next:

  • Host parameters

    Parameter Range Resolution Error
    Flue gas temperature (0~500)℃ 1℃ ±3.0℃
    Flue gas static pressure (-30~30)kPa 0.01kPa ±2.0%FS
    Flue gas dynamic pressure (0~2000)kPa 0.01kPa ±2.0%FS
    Sampling flowrate ≥1L/min 0.1L/min  
    Total pressure (60~130)kPa 0.01kPa ±0.5kPa
    Excess air coefficient 1~99.99 0.01 ±2.5%
    Working temperature (-20~50)℃    
    Data storage >1000000 groups
    Power Supply AC220V±10%,50Hz
    Size (length 370×width 170×height 305)mm
    Weight About 7kg(battery include)
    Noise <65dB(A)
    Power consumption <120W

    Flue gas sampling parameters

    Parameter

    Range

    Resolution

    Error

    S02

    Low range:(0~430)mg/m3

    High range:(0~5720)mg/m3

    0.1 mg/m3

    l relative error:± 3%l Repeatability:≤1.5%l Response time:≤90sl Stability:Indication change within 1h<5%l Detection limit:SO2≤2mg/m³NO≤1mg/m³NO2≤2mg/m³

    NO

    Low range:(0~200)mg/m3

    High range:(0~1340)mg/m3

    0.1 mg/m3

    NO2

    Low range:(0~300)mg/m3

    High range:(0~1000)mg/m3

    0.1 mg/m3

    O2

    (0-30)%

    0.1%